Search results for "Pulmonary vein"
showing 10 items of 18 documents
Value of contrast-enhanced MR angiography and helical CT angiography in chronic thromboembolic pulmonary hypertension.
2003
The aim of this study was to evaluate the diagnostic value of contrast-enhanced MR angiography (ce MRA) and helical CT angiography (CTA) of the pulmonary arteries in the preoperative workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH). The ce MRA and CTA studies of 32 patients were included in this retrospective evaluation. Image quality was scored by two independent blinded observers. Data sets were assessed for number of patent segmental, subsegmental arteries, and number of vascular segments with thrombotic wall thickening, intraluminal webs, and abnormal proximal to distal tapering. Image quality for MRA/CTA was scored excellent in 16 of 16, good in 11 of 14, m…
Electrocardiographic Imaging for Atrial Fibrillation: A Perspective From Computer Models and Animal Experiments to Clinical Value
2021
[EN] Electrocardiographic imaging (ECGI) is a technique to reconstruct non-invasively the electrical activity on the heart surface from body-surface potential recordings and geometric information of the torso and the heart. ECGI has shown scientific and clinical value when used to characterize and treat both atrial and ventricular arrhythmias. Regarding atrial fibrillation (AF), the characterization of the electrical propagation and the underlying substrate favoring AF is inherently more challenging than for ventricular arrhythmias, due to the progressive and heterogeneous nature of the disease and its manifestation, the small volume and wall thickness of the atria, and the relatively large…
A case report of pulmonary vein isolation performed in a patient with polysplenia and interrupted inferior vena cava
2021
Abstract Background Pulmonary vein isolation (PVI) has entrenched itself as one of the main approaches for the treatment of paroxysmal symptomatic atrial fibrillation (AF). Pulmonary vein isolation prevents focal triggers from pulmonary veins from initiating AF paroxysms. As standard—PVI is performed through the inferior vena cava (IVC) approach, through the femoral vein. However, there are conditions when this approach is not appropriate or is not available. Case summary We report a case of a 53-year-old male who was referred to Pauls Stradins Clinical University Hospital for PVI due to worsening AF. Due to the rare anatomical variant of the venous system, the standard approach to PVI coul…
Arrhythmia Termination Versus Elimination of Dormant Pulmonary Vein Conduction as a Procedural End Point of Catheter Ablation for Paroxysmal Atrial F…
2015
Background— Pulmonary vein isolation (PVI) is still associated with a substantial number of arrhythmia recurrences in paroxysmal atrial fibrillation (AF). This prospective, randomized study aimed to compare 2 different procedural strategies. Methods and Results— A total of 152 patients undergoing de novo ablation for paroxysmal AF were randomized to 2 different treatment arms. The procedure in group A consisted of PVI exclusively. In this group, all isolated PVs were challenged with adenosine to reveal and ablate dormant conduction. In group B, PVI was performed with the patient either in spontaneous or in induced AF. If AF did not terminate with PVI, ablation was continued by targeting ex…
Impact of biatrial defragmentation in patients with paroxysmal atrial fibrillation: Results from a randomized prospective study
2014
Single procedure success rates of pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF) are still unsatisfactory. In patients with persistent atrial fibrillation (AF), ablation of complex fractionated atrial electrograms (CFAEs) after PVI results in improved outcomes.We aimed to investigate if PAF-patients with intraprocedurally sustained AF after PVI might benefit from additional CFAE ablation.A total of 1134 consecutive patients underwent a first catheter ablation procedure of PAF between June 2008 and December 2012. In most patients, AF was either not inducible or terminated during PVI. In 68 patients (6%), AF sustained after successful PVI. These patients …
Segmental pulmonary vein ablation: success rates with and without exclusion of areas adjacent to the esophagus.
2008
Background: Catheter ablation has become the first line of therapy in patients with symptomatic recurrent, drug-refractory atrial fibrillation (AF). The occurrence of an atrioesophageal fistula is a rare but serious complication after AF-ablation procedures. This risk is even present during segmental pulmonary vein (PV) ablation procedures because the esophagus does frequently have a very close anatomical relationship to the right or left PV ostia. The aim of the present study was to analyze whether the exclusion of areas adjacent to the esophagus does have a significant effect on the success rates after segmental pulmonary vein ablation procedures. Methods: Forty-three consecutive patients…
5-Year Outcome of Pulmonary Vein Isolation by Loss of Pace Capture on the Ablation Line Versus Electrical Circumferential Pulmonary Vein Isolation
2017
This study sought to compare long-term arrhythmia-free survival between electrical circumferential pulmonary vein isolation (PVI) and PVI with the endpoint of unexcitability along the ablation line.PVI is the standard ablation strategy of paroxysmal atrial fibrillation, although arrhythmia recurrence in long-term follow-up (FU) is high. The endpoint of unexcitability along the ablation line results in decreased arrhythmia recurrence compared to electrical PVI in 1-year FU.Seventy-four consecutive patients (age 62.5 ± 10.6 years; 70.3% male) with de novo paroxysmal atrial fibrillation who were initially included in our randomized trial and underwent catheter ablation at our institution were …
Simplifying atrial fibrillation ablation: how far can we go?
2013
The procedural end point of electrical isolation of the pulmonary veins (PVs) for the treatment of atrial fibrillation (AF) has been debated extensively. After identifying the PVs as the dominant arrhythmogenic site of paroxysmal AF, 2 fundamentally different approaches to the interventional treatment of AF were introduced. Haissaguerre et al developed a technique to electrically isolate the PVs by targeting electrophysiological (EP) breakthroughs from the left atrium to the PVs guided by a circular mapping catheter. In contrast, Pappone et al implemented an anatomical approach that used circumferential ablation lines around the PVs guided by a 3-dimensional mapping system. This latter appr…
Nerves projecting from the intrinsic cardiac ganglia of the pulmonary veins modulate sinoatrial node pacemaker function
2013
Rationale: Autonomic nerves from sinoatrial node (SAN) ganglia are known to regulate SAN function. However, it is unclear whether remote pulmonary vein ganglia (PVG) also modulate SAN pacemaker rhythm. Objective: To investigate whether in the mouse heart PVG modulate SAN function. Methods and Results: In hearts from 45 C57BL and 7 Connexin40+/GFP mice, we used tyrosine-hydroxylase (TH) and choline-acetyltransferase (ChAT) immunofluorescence labeling to characterize adrenergic and cholinergic elements, repectively, within the PVG and SAN. PVG project postganglionic nerves to the SAN. TH and ChAT stained nerves, enter the SAN as an extensive, dense mesh-like neural network. Neurons in PVG are…
Isolation of the left atrial surface from cardiac multi-detector CT images based on marker controlled watershed segmentation
2006
The delineation of left atrium (LA) and pulmonary veins (PVs) anatomy from high resolution images holds importance for atrial fibrillation (AF) investigation and treatment. In this study, a semiautomatic segmentation procedure for LA and PVs inner surface from contrast enhanced CT data was developed. The procedure consists of a three dimensional marker controlled watershed segmentation applied to the external morphological gradient, followed by variable threshold surface extraction from the original intensity image. A preliminary anisotropic non-linear filtering was implemented to improve the S/N ratio of CT images. The performance of segmentation was evaluated on cardiac CT scans of 12 AF …